Series 63™

Products » Residential Boilers » Series 63™
 

The Series 63™ boiler from Peerless is a residential, gas-fired boiler for hot water or steam systems. Shipped as knockdown (factory assembled sections), the boiler comes in seven sizes ranging from three to six sections (steam boilers are also available as packaged units). The Series 63™ boiler is available for either natural or LP gas and has AFUE ratings of up to 82%. A single vent draft hood allows for natural draft (chimney) venting. The significant water content of the Series 63™ boiler makes it ideal for large volume hot water applications. Standard equipment on the Series 63™ boiler includes steel push nipples that provide a permanent, watertight seal between sections. A probe type low water cut-off is standard on steam boilers. All Series 63™ boilers include standard standing pilot ignition (spark ignition is available as an option), Honeywell operating controls, vent damper and a slide-in, pre-assembled burner tray. A deluxe, insulated, enameled steel jacket completely encloses gas valves and burners, and reduces boiler heat loss. The low profile design of the Series 63™ boiler works well for limited clearance installations.

Type: Residential
Construction: Cast Iron
Fuel: Gas-Fired (Natural or LP)
Input: 88.5 to 287.5 MBH
Output: 73 to 241 MBH
Venting: Natural Draft
Trim: Water or Steam
Ignition: Standing Pilot or Spark

 

  • Packaged or Knockdown Residential Gas Boilers
  • Natural or LP Gas
  • Natural Draft (Chimney) Venting
  • Electrically Operated Vent Damper
  • Large Water Content
  • Low Profile Design
  • Standing Pilot or Spark Ignition
  • Steam or Hot Water Boilers
  • Skim Tapping for Cleaning Steam Boilers

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

Series 63™ Water Content Approx. Shipping Weight, lb
Model Number Input, MBH Heating Capacity3, MBH Net I=B=R Ratings1 Standing Pilot AFUE3 Spark Ignition AFUE3
Water Steam Steam, sqft Steam, MBH Water, MBH Water, % Steam, % Water, % Steam, % Water, gal Steam, gal
63-03L 88.5 73 74 233 56 63 80.9 80.6 82.4 83.0 13.2 9.3 465
63-03 118 99 98 308 74 86 82.1 81.2 83.5 82.6 13.2 9.3 465
63-04L 147.5 123 123 383 92 107 81.4 80.6 82.7 82.6 15.6 10.8 576
63-04 177 148 147 458 110 129 82.1 81.0 83.4 82.4 15.6 10.8 576
63-05L 206.5 172 171 533 129 150 81.9 80.7 82.9 82.3 18.0 12.4 700
63-05 236 198 196 613 147 172 82.2 80.9 83.3 82.2 18.0 12.4 700
63-06 287.5 241 238 746 179 210 82.3 80.7 83.2 82.0 20.4 13.9 812

1 Net I=B=R Ratings are based on DOE Heating Capacity less an allowance for normal piping and pickup as determined by the Testing and Rating Standard for Low Pressure Cast Iron Heating Boilers of the Hydronics Institute. Water ratings are based on a piping and pickup factor of 1.15. Steam ratings are based on a piping and pickup factor of 1.33. Consult PB Heat before selecting a boiler for gravity hot water installations or for installations having unusual piping and pickup requirements such as exposed piping, night set-back, etc. Ratings shown are for elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.

2 Minimum Natural Gas Inlet Pressure exceptions: 63-04 STDG 5.3”; 63-06 STDG 5.5”; 63-06 SPRK 5.3”.

3 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government tests. Before purchasing this appliance, read important information about its estimated annual energy consumption or energy efficiency rating that is available from your retailer.

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

Series 63™ Boiler Dimensions

Boiler Model Width "A" Depth "B" Top to Floor "C" Jacket Depth "D" Rear of Jacket to c/l of Flue"E" Flue Size"F"
63-03L 16 1/8" 37 1/4" 36 3/8" 28 1/8" 5 5/8" 6"
63-03 16 1/8" 37 1/4" 36 3/8" 28 1/8" 5 5/8" 6"
63-04L 20 3/8" 37 1/4" 36 3/8" 28 1/8" 5 1/8" 7"
63-04 20 3/8" 37 1/4" 36 3/8" 28 1/8" 5 1/8" 7"
63-05L 24 5/8" 39 1/4" 36 3/8" 28 1/8" 6 5/8" 8"
63-05 24 5/8" 39 1/4" 36 3/8" 28 1/8" 6 5/8" 8"
63-06 28 7/8" 39 1/4" 36 3/8" 28 1/8" 6 1/8" 9"

Tapping Locations

Tap ID Size N.P.T. Steam Water
j 1 14" Skim Tapping Skim Tapping
K 1" Tank Supply/Limit N/A
L 1" Tank Return N/A
M 3/4" Boiler Drain Boiler Drain
N 3" Supply Supply
P 2 12" Return Return
R 3/4" Safety Valve Relief Valve
S 1/2" Gauge Glass N/A
T 3/4" Primary Probe Low Water Cut-Off N/A
U 3/4" Primary Limit Primary Limit
V 3/4" Secondary Limit Pressure/Temperature Gauge
W 3/4" Pressure Gauge Secondary Limit
X 3/4" Secondary Probe Low Water Cut-Off N/A

Don't see the information you need? See the "Related Documents" tab for product resource downloads.